Skip to main content

INDUSTRIAL SECONDARY CONTAINMENT

Spill Containment Berms for Equipment, Vehicles and Industrial Sites

Five containment berm structures for different equipment footprints, access requirements and deployment conditions. Custom dimensions and configurations are available for project-based applications.

5 Berm Structures · Custom Dimensions · Project-Based Configuration · Industrial Secondary Containment
L-bracket spill containment berm deployed on site

Containment Definition & Scope

Secondary Containment for Spills and Leaks

Spill containment berms create a temporary or project-specific secondary containment area around equipment, tanks, drums, vehicles and other potential spill sources.

They are designed for secondary containment and are not intended to replace primary liquid storage tanks.

Support Structures & Selection

Choose the Right Spill Containment Berm

Five support structures are available for different equipment sizes, site conditions and deployment requirements. Each suits a different balance of wall stability, portability, setup speed and storage volume.

★ MOST RECOMMENDED

L-Bracket Support Spill Containment Berm

Stable Support. Fast Setup. Easy Storage.

Angle brackets provide reliable sidewall support while keeping the berm simple to assemble, fold and transport. This configuration offers a practical balance of stability, portability and deployment speed for a wide range of industrial containment applications.

Best For

  • Generators
  • Drums and IBCs
  • Machinery
  • Maintenance areas
  • Fuel handling equipment
  • General industrial containment

Advantages

Stable Sidewall Support: Reliable wall support without requiring a complete external tube frame.

Fast Assembly: Individual supports can be positioned quickly during deployment.

Easy to Store: Folds flat after use for compact transport and storage.

Versatile Application: Covers broad standard industrial spill-containment projects.

L-Bracket Spill Containment Berm deployed on site

Specialized Applications

Alternative Berm Structures for Specific Site Requirements

Four alternative berm structures are available for specialised operational requirements where the standard configuration does not suit the site.

Spill containment berm with external supports for added wall stability
02 EXTERNAL SUPPORT

Outside Support Spill Containment Berm

External Support for Added Wall Stability

External wall supports reinforce the containment barrier while keeping the internal berm area clear for equipment and storage.

Suitable For: Industrial equipment · Temporary containment · Drum storage · Applications requiring external wall support
External Support Quick Setup Portable
View Details →
Galvanized-tube frame spill containment berm for larger containment volumes
03 HEAVY-DUTY FRAME

Galvanized-Tube Support Spill Containment Berm

Rigid Frame for Larger Containment Areas

A galvanized tube framework provides stronger structural support for larger containment footprints and more demanding industrial installations.

Suitable For: Larger machinery · Large equipment footprints · Outdoor sites · Tank and equipment containment · Stronger wall support
Rigid Frame Larger Footprints Heavy-Duty Support
View Details →
Inflatable-wall spill containment berm, portable without rigid supports
04 INFLATABLE WALL

Inflatable-Wall Spill Containment Berm

Portable Containment Without Rigid Supports

Inflatable sidewalls form the containment boundary without a separate rigid support structure, providing a portable option for temporary deployment.

Suitable For: Temporary sites · Portable containment · Rapid deployment · Applications where rigid supports are inconvenient
Inflatable Wall Portable Compact Storage
View Details →
Sponge-filled wall spill containment berm, lightweight flexible-wall design
05 SPONGE-FILLED WALL

Sponge-Filled Wall Spill Containment Berm

Lightweight Flexible-Wall Containment

Soft sponge-filled walls create a lightweight containment boundary for applications where fast handling and compact storage are priorities.

Suitable For: Temporary containment · Light-duty equipment · Portable applications · Quick deployment
Lightweight Flexible Wall Easy Storage
View Details →

Side-by-Side Comparison

Compare the 5 Spill Berm Structures

Compare support method, portability and typical application before choosing a configuration.

Feature ★ L-Bracket (Recommended) Outside Support Galvanized Tube Inflatable Wall Sponge-Filled
Support Type L-brackets External supports Galvanized tube frame Inflatable wall Sponge-filled wall
Typical Use General industrial External-supported containment Larger installations Portable / temporary Lightweight / temporary
Structural Support High / balanced High Very High Application-specific Light-duty
Setup Speed Fast Fast Moderate Fast Very Fast
Portability High High Medium High Very High
Storage Compact Compact More components Big Pack Big Pack
Larger Footprints Good Good Best suited Project-specific Limited
General Use ★ Recommended Site-specific Heavy-duty Special requirement Light-duty
Positioning ★ Best all-round choice Alternative Heavy-duty option Portable option Lightweight option

Not sure which structure to choose?

Start with the L-Bracket configuration and tell us about your application and equipment footprint.

Get a Berm Recommendation →

Quick Selection Matrix

Which Spill Berm Should You Choose?

Need a reliable berm for general industrial use?

Choose L-Bracket Support

Suited to standard projects where stability, portability and quick assembly are all important.

Need stronger structural support for a larger footprint?

Choose Galvanized-Tube Support

Suitable for larger machinery, equipment and containment areas requiring a more rigid framework.

Prefer an externally supported wall system?

Choose Outside Support

External supports reinforce the berm wall while leaving the internal containment area unobstructed.

Need a portable system without rigid brackets?

Choose Inflatable Wall

Consider an inflatable-wall configuration when portability and temporary deployment are priorities.

Need a lightweight temporary containment solution?

Choose Sponge-Filled Wall

Suitable for lighter-duty applications where quick deployment and storage are important.

Engineering Sizing Consultation

Configure the Berm Around Your Equipment

Berm dimensions should be selected around the actual equipment footprint, required clearance and containment volume—not only from a standard size list.

Wall Height: 0.2 m – 0.7 m (Configured per Project)

Tell Us Your Dimensions:

  • • Equipment length & width
  • • Required berm clearance around equipment
  • • Required wall height (0.2 m – 0.7 m)
  • • Equipment type (generator, transformer, vehicle)
  • • Vehicle access / drive-in requirements
  • • Contained liquid / medium
  • • Quantity required

Send us the equipment dimensions if you are unsure about the berm size. We can review the required footprint before quotation.

Send Equipment Dimensions →

PRODUCT REFERENCES

Spill Berms We’ve Made

Examples of spill containment berms manufactured for different equipment footprints, wall structures and site requirements.

6x4m L-Bracket Spill Containment Berm

L-Bracket Spill Berm

6 × 4 × 0.3m · Industrial Generator

10x6m L-Bracket Support Berm for bulk containment

L-Bracket Spill Berm

10 × 6 × 0.3m · Bulk Liquid Containment

Looking for a custom berm footprint or wall height?

Send Your Required Berm Size →

Fabric & Exposure

Material and Liquid Compatibility

Material 01

PVC Construction

FUUSHAN spill containment berms are manufactured using flexible PVC-coated materials selected according to the required structure and application.

Reinforced seams and heavy-duty corner construction help maintain liquid barrier integrity under operational stress.

Review 02

Compatibility Review

Liquid compatibility should be confirmed according to the actual contained medium, concentration, temperature and expected exposure conditions.

Spill berms provide secondary containment for incidental drips and leaks; universal fuel or chemical immunity is not assumed.

Checklist 03

Request These Details for Chemical Review

• Liquid / chemical name
• Concentration (if applicable)
• Operating temperature
• Expected contact duration
• Indoor or outdoor installation

Operations & Sites

Industrial Spill Containment Applications

Fuel Transfer & Refueling

Containment around temporary fuel-transfer, dispensing and mobile refueling operations.

Drum & IBC Storage

Secondary containment for chemical drums, IBC totes and temporary liquid storage depots.

Machinery & Equipment

Containment around industrial, mining, drilling and construction machinery prone to oil leaks.

Vehicle & Tanker Operations

Larger berm configurations for maintenance, washdown, fuel tankers and mobile fleet equipment.

Generators & Transformers

Secondary containment around fuel-powered generator sets, substations and oil-cooled transformers.

Maintenance & Workshop Areas

Portable containment for service bays, machinery teardown, repair and maintenance operations.

Production Process

Built for Project-Based Industrial Use

01

Material Preparation

PVC materials are precision cut according to the confirmed berm dimensions and wall height.

02

Welding

Panels, reinforced corners and seam details are fabricated through controlled hot-air welding processes.

03

Support Installation

Brackets, frames or other wall-support components are prepared according to the selected structure.

04

Inspection & Packing

The finished berm and support components are checked and organized before export packing.

Direct Manufacturer

Why Work with FUUSHAN

Five Berm Structures

Multiple wall-support configurations for different equipment, access and site requirements.

Custom Equipment Footprints

Length, width and wall configuration can be reviewed around the actual equipment dimensions.

In-House Fabrication

Material cutting, welding and structural preparation are managed directly through our production facility.

Project-Based Export Supply

We support B2B projects requiring configuration review, production coordination and export packing.

Delivered Project Record

Spill Containment in Real Projects

KEEP READING

Related Applications and Guides

GUIDE

How to Choose a Flexible Tank Manufacturer

Check materials, welding, inspection and custom capability before you commit to a supplier.

Read more →
APPLICATION

Industrial Secondary Containment

Portable secondary containment berms for fuel handling, drums, IBCs, equipment and vehicles, with project-specific size, wall height and material.

Read more →

FAQ

Frequently Asked Questions

What is a spill containment berm used for?

Spill containment berms create a secondary containment area around equipment, drums, tanks, vehicles or other potential spill sources.

Which spill berm structure do you recommend?

Selection depends on equipment footprint, site conditions, access requirements and containment volume rather than on one best structure. Send us the equipment dimensions and operating conditions and we will review the suitable configurations before quotation.

What is the difference between L-Bracket and galvanized-tube support?

L-Bracket systems use individual wall supports and are generally easier to deploy and store. Galvanized-tube systems use a more rigid frame and may be better suited to larger containment footprints or applications requiring greater structural support.

Can the berm size be customized?

Yes. Berm dimensions can be reviewed according to equipment footprint, required clearance, wall height and project conditions.

Can you recommend a berm size from my equipment dimensions?

Yes. Provide the equipment length, width and required operating clearance, and we can review the required berm footprint before quotation.

Can spill berms contain fuel or chemicals?

Material compatibility should be confirmed according to the exact liquid, concentration, temperature and expected exposure conditions.

Are spill berms primary storage tanks?

No. Spill containment berms are designed for secondary containment and should not be treated as primary liquid storage tanks.

Explore More

Related Products

Project-configured flexible tanks and containment products from the same manufacturing line.

REQUEST FOR QUOTATION (RFQ)

Request a Spill Containment Berm Quote

Share your equipment footprint (length × width), required wall height (0.2–0.7 m), liquid type, quantity and destination. Our engineering team reviews the required berm area and provides a formal quotation within 24 hours.

Not sure which structure to choose? Start with the L-Bracket configuration and tell us about your application.

Spill Containment Berms for EquipmentB2B Manufacturing
Request Quote